User Manual

Preface 

Thank you very much for purchasing and using EnemaPro. To ensure safe and effective use, please read this manual carefully before first use. According to copyright law, it is strictly forbidden to reprint any part of this manual without authorization. 

Precautions for Use 

1. EnemaPro is a rechargeable battery-powered device. Please select a qualified power adapter or 5V USB interface, fully charge the device before first use, and do not use it while charging. 

2. If using an optional power adapter, ensure it meets appropriate safety standards (such as GB 9706.1-2007) and follow all corresponding instructions. 

3. To prevent injury, children should not use EnemaPro unsupervised, and it should always be kept out of their reach. 

4. Do not pull out the power cord with wet hands. 

5. Do not use EnemaPro in the bath or submerge it in water. 

6. Avoid placing or storing the device where it may fall or be exposed to water. 

7. Regularly inspect the power supply and charging cable for damage, especially before each use. 

8. Do not use EnemaPro if the charging line or plug is damaged, if the device is malfunctioning, or if it has been exposed to liquids. 

9. Avoid inserting any foreign objects into the nozzle or power socket. 

10. Do not use EnemaPro in areas where oxygen or aerosol sprays are in use. 

11. Keep the device away from hot surfaces, such as stoves or ovens, to prevent overheating or damage. 

12. EnemaPro is specifically designed to deliver gentle colonic irrigation. Do not use this device for any other purpose or introduce liquids into areas not intended for use. 

13. Avoid using EnemaPro near high-frequency medical or RF equipment to prevent electromagnetic interference. 

14. EnemaPro has a built-in lithium battery; it should only be used in an environment with an ambient temperature between 5°C and 40°C. 

15. Store EnemaPro in a clean, ventilated, moisture-proof, dust-proof area free from toxic gases and corrosive substances to ensure optimal performance and longevity.

16. After the replacement parts of EnemaPro and the service life of the device have expired, please dispose of them according to national guidelines for electronic products to ensure environmental protection.

17. The nozzle is made of medical-grade silicone, which is non-toxic and hypoallergenic for human use.

18. Please note that the EnemaPro nozzle tip is intended for single-person use only and should not be shared to prevent bacterial contamination.

1 Overview

1.1 Product Introduction

EnemaPro uses mechanical pressure to deliver a gentle, controlled flow of water into the lower colon. This flow helps to alleviate constipation by loosening and flushing out waste material, restoring the natural balance of the digestive system, and supporting colonic health.

1.2 Scope of Application

  • Suitable for relieving constipation and facilitating gentle colon cleansing.

1.3 Contraindications

EnemaPro is not recommended for individuals with the following conditions:

  • Those with severe gastrointestinal issues should consult a doctor before use.
  • Do not use if there is a complete blockage in the lower colon.
  • Children under 5 years old should only use EnemaPro under the guidance of a healthcare professional.
  • If any bleeding occurs, stop using EnemaPro and seek medical advice.
  • Avoid using EnemaPro if suffering from gastrointestinal infections, and only resume use once fully recovered.
  • Not recommended for patients with recent abdominal trauma or surgical incisions.

1.4 Product Features

  • Gentle, pulsating water flow.
  • Adjustable settings for different comfort levels.
  • Designed for ease of use by multiple household members.
  • Portable and easy to carry.
  • USB rechargeable, making it easy to operate, time-saving, and comfortable.
  • Suitable for individuals with different needs and preferences.

1.5 Technical Performance Specifications

1.5.1 Main Technical Specifications

  • Power Supply Typed.c.3.7V
    Operation ModeContinuous operation
    Maximum Water Pressure0.63MPa
    Noise Level≤ 80dB(A)


    1.5.2 Power Supply Details

    • Input Power: DC5V = 1A
    • Charging Cable Length: 1.2 meters

    1.5.3 Device Classification

    • Electric Shock Protection Classification: Internal power supply, specific to the device
    • Electric Shock Prevention Level: BF type application part
    • General equipment without liquid inlet prevention
    • Not suitable for use with flammable anesthetic gases mixed with air or nitrous oxide
    • Not designed for anti-defibrillation applications
    • No signal output or input components
    • Non-permanent installation required
    • Electromagnetic compatibility meets YY0505-2012 standards

    1.6 Operating Environment

    • Ambient Temperature: 5°C ~ 40°C
    • Relative Humidity: ≤ 90%
    • Atmospheric Pressure: 700hPa ~ 1060hPa
    • Water Temperature: 35°C ~ 39°C

    1.7 Transportation and Storage Conditions

    To avoid device failure, follow these storage guidelines:

    • Storage Temperature: -20°C ~ +70°C
      • Relative Humidity: ≤ 95% (non-condensing)
    • Atmospheric Pressure: 700hPa ~ 1060hPa
    • Do not store in locations where water may splash on the device.
    • Avoid storing in environments exposed to extreme atmospheric conditions, temperature fluctuations, humidity, air pollutants, sunlight, dust, sea air, sulfur, or other harmful elements. Ensure the device is positioned stably, avoiding tilting, vibration, and impact.

    These guidelines also apply during transportation.

    • Do not store in areas where chemicals or gases are present.
    • If EnemaPro will not be used for an extended period, please unplug the power cord.
    • Operating Environment: Avoid areas with electromagnetic interference or excessive vibration.

    2. Product Composition

    2.1 Structure composition: it is composed of water pump, water tank, nozzle head, and power line.

    2.2 Instrument Diagram                                                                                                                                                                                                                                    

3. How to Use the Product

3.1 Sterilization and Disinfection

  • The Automatic Enema Pump is a non-sterile and reusable medical device, which needs to be cleaned and disinfected before being used for the first time.
  • The specific operation method is as follows:

3.1.1 Manual Cleaning (water temperature should be 15°C – 30°C)

  • a. Flushing: Flush the nozzle and water tank under flowing water to preliminarily remove pollutants.
  • b. Washing: After washing, if there are dry and solid stains, soak them in a medical cleaning agent first, and then scrub them with a clean soft cloth.
  • c. Rinse: After washing, rinse with flowing water.
  • d. Rinse with distilled or soft water.

3.1.2 Disinfection

  • Pour purified water at 93°C – 100°C into the water tank for disinfection for 1 minute, and use after drying.
  • StartBefore the first use, please fully charge the host, plug the power charging cable into the charging socket, and turn on the power. The product cannot be used while charging. (When charging, the indicator lights flash; when fully charged, the four indicator lights are always on). 
  • Install and Remove the NozzleInsert the nozzle into the middle hole of the nozzle until it clicks. If replacing or removing the nozzle, press and hold the nozzle locking key, and then take out the nozzle.
  • Prepare Filtered Water and Water TankAdjust the filtered water to the appropriate temperature (37 – 40 degrees). A saline solution compatible with EnemaPro may be added if preferred, mix by stirring then screw the water tank on clockwise according to the prompts of the fuselage. Contact EnemaPro for Saline product recommendations.
  • Remove the Water TankHold the upper and lower parts with the left and right hands respectively, as shown in the figure, turn the EnemaPro pump to the right, and then pull it up to remove the water tank. 
  • After UseTurn off the equipment, unload the water tank, clear the residual liquid in the water tank, turn on the equipment, discharge the residual liquid in the EnemaPro pump until no more water is discharged, and then turn off the equipment.

3.3 Startup and use

3.3.1 Usage for Colonic Irrigation and Constipation relief

  • Power On/Off: Press the switch button to turn the machine on or off.
  • Selecting a Mode: Use the mode button to choose from three settings:
  • Low (0.026 PSI): Provides a gentle flow, similar to a watering can, ideal for first-time users or sensitive needs.
  • Pulse (0.032 PSI): Offers intermittent water flow for enhanced colon stimulation at low pressure.
  • High (0.072 PSI): Delivers a stronger flow for users needing more intense relief.
  • EnemaPro starts in the standard mode upon powering on. New users are encouraged to start with Low to allow their body to adjust.
  • Preparing for Use: Apply a safe lubricant (silicone or water-based) to the nozzle or tube tip. Choose a comfortable position; EnemaPro can be used while standing or lying down. Slowly insert the lubricated nozzle or tube to ensure a secure and comfortable fit.
  • Using EnemaPro: After insertion, water will flow according to the selected mode. Start in Low mode to introduce water gently, then adjust to Pulse or High as preferred.
  • Precautions: If any discomfort arises, switch back to Low or turn off the device briefly. Maintain a relaxed posture to help water reach the intended area smoothly. EnemaPro’s gentle pressure settings and versatile positioning make it a reliable tool for effective constipation relief.

Tips for use

First-Time Use:

  • Begin with the Low (0.026 PSI) setting for a gentle introduction. Once accustomed to EnemaPro, you may use the High (0.072 PSI) setting for a more thorough cleanse.
  • It’s important to remain relaxed throughout the process. Consider taking deep breaths and avoid clenching to facilitate water flow.

⚠️ Attention:

  • If water flow becomes obstructed or there is resistance, avoid increasing pressure to prevent potential discomfort or injury.
  • If water isn’t moving effectively through the colon or you feel any unusual pressure, discontinue use and allow the body to relax before attempting again.

⚠️ Warnings:

  • Monitor your body’s response to pressure during irrigation. If you feel discomfort or bloating, reduce to the Low setting or pause to let the body adjust.
  • If you experience significant discomfort during or after use, stop immediately and consult a healthcare provider for guidance.

By starting slowly and being mindful of these tips, you can use EnemaPro safely and effectively for colonic irrigation.

 

After use:

Do not use this product for more than 8 minutes each time. After washing, turn off the equipment, pour out the residual washing liquid in the water tank, and then pour about 100 mL clean water into the water tank. Turn on the machine until the clean water is used up, so as to avoid the corrosion and damage of the residual washing liquid in the machine to the interior of the machine.

4 Maintenance and cleaning of Automatic Enema Pump

 

4.1 Daily cleaning and maintenance, after each use:

  • After each use, turn off the equipment, pour out the residual saline in the water tank (if using), and then pour about 100 mL clean water into the water tank, and turn on the machine until the clean water is used up, so as to avoid the corrosion damage caused by the residual saline in the machine. Please pull out the plug or charging wire after use.
  • Wipe the external surface of the equipment with a soft wet cloth;
  • Do not use cleaning agent for the main pump.
  • If you want to clean the inner wall of the water tank, remove the water tank from the main engine and flush the water tank with running water.
  • Deposits left behind by non-recommended cleaning fluids can clog your machine. Only use clean water or Castile soap that is safe for humans.
  • Note: the use of some antibacterial cleaning solution may cause damage to the machine or shorten the service life of the product. Do not immerse the product in water.
  • After using the nozzle, please wash it with clean water / Castile soap and dry it.
  • Proper use of the EnemaPro’s battery is important for maintaining its longevity. Low battery power won’t cause immediate safety issues, but frequently using the device with a low charge can degrade the battery over time. To protect the battery, allow it to charge fully when recharging and avoid overcharging it.
  • When not in use for a long time, the battery should be in the state of partial charge;
  • Complete a charging cycle for lithium battery every month.

4.2 Check the product at least once a month, whether it is used regularly or not

 

  • Whether the product surface is damaged;
  • Whether the power supply charging line is damaged;
  • Whether the water pipes and nozzles are damaged or blocked;
  • Whether the detachable parts are lost and the socket is smooth.

5 Troubleshooting Guide

The following table shows the common faults that may appear in the process of use and their troubleshooting methods. If you have consistent conditions in use, please refer to the processing.

 

ProblemReasonSolution
Unable to discharge water or insufficient water pressureInsufficient power or clogged nozzleUse or replace the nozzle after full charge
Nozzle crackingThe nozzle is seriously wornReplace the nozzle with a new one
The device failed to startThe motor is not working or the power is insufficientCharging; if charging still cannot start, contact EnemaPro support for assistance
Stop working suddenlyProduct 2-minute anti-touch designTurn it on again
It can only work for a few minutes after full chargeThe battery life is overContact EnemaPro support (dismantling the pump will result in void of warrantee)

In use, if the above situations cannot be ruled out or other than the above fault, please contact EnemaPro support.

 

Parts List

One manual, one Automatic Pump, one water tank, one charging line, and five nozzles, one 1.5m tube, 2 plastic connectors, one bag.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shopping Cart